SOLUTION 01

Recessed LED Video Wall Solution for Existing Spaces

Make the LED display fit your space — not the other way around.

When the architectural opening is already built or the installation depth is limited, we design a recessed LED video wall around the actual site conditions — including module layout, custom steel structure, electronics placement and front maintenance.

Recessed LED video wall opening before installation in Turkey
SOLUTION 02

When the Wall Is Already Built

Different constraints, different solution.

Most LED video wall projects allow the installation space and supporting structure to be planned around the display. But when the wall, opening or interior finish is already completed, the process is reversed. The LED system must be designed around the available width, height, depth and maintenance conditions.

Standard Installation

New wall or frame, flexible installation space.

01
Define the LED display size

Determine the required screen size and pixel pitch.

02
Design the steel structure

Prepare the supporting structure for the LED display.

03
Prepare the installation space

Complete the wall or frame around the planned LED system.

The installation space can be planned around the LED display.

Existing-Space Installation

Existing opening, fixed dimensions and limited depth.

01
Measure the existing opening

Confirm the available width, height and depth (W × H × D).

02
Calculate the module layout

Match the module dimensions to the available installation area.

03
Design the custom structure

Plan the steel structure, power supplies, receiving cards and cabling within the available depth.

04
Plan front maintenance

Keep modules and internal components accessible from the front when rear access is unavailable.

The LED system is designed around the available space.

SOLUTION 03

Key Measurements and Considerations

Before designing a recessed LED wall, these are the key factors you need to confirm.

When the wall or opening is already built, the LED system must match the available space and technical conditions. The following measurements and considerations help us determine a practical module layout, structure design and maintenance approach before installation.

01

Opening Size

Width × Height (W × H)

Measure the actual opening size accurately and confirm any tolerances or irregularities on all sides.

02

Installation Depth

Available Depth (D)

Measure the usable depth from the front surface to the back wall. This affects the steel structure, electronics placement and cable routing.

03

Module Size & Layout

Match to the Available Space

Select suitable module dimensions and calculate the layout around the actual opening size to achieve a clean and practical installation.

04

Maintenance Access

Front or Rear Access

Confirm whether rear access is available. If rear access is limited or unavailable, the LED system should be designed for front maintenance.

05

Power and Signal

Location and Routing

Plan the locations of power supplies, receiving cards, signal cables and power cables within the available installation space.

06

Surrounding Conditions

Wall Material and Structure

Check the wall material, flatness, fixing conditions and any obstacles such as columns, pipes or existing wiring.

Accurate site measurements are the foundation of a reliable recessed LED wall design.

The more accurate the site information, the more precisely the LED system, steel structure and maintenance access can be planned.

SOLUTION 04

The Critical Constraint: Installation Depth

The recessed opening was already built and could not be modified.

turkey recessed led wall installation depth 2026 01
PROJECT CONDITION
Existing wall recess
Approx. 40 mm

The original wall recess depth was approximately 40 mm and could not be changed. The surrounding wooden finish provided additional usable depth, but the total installation thickness still had to remain within the finished wall profile.

The challenge was not simply fitting an LED module into the opening. The total installation depth had to account for:

All components had to work together within the available space.

SOLUTION 05

How We Designed Around the Available Depth

The available space could not be changed. So every part of the LED system had to be planned around it.

01
START WITH THE FIXED SPACE

3250 × 500 mm Existing Opening

We confirmed the exact opening size and checked all tolerances on site. The existing opening defined the maximum installation area, and the display had to work within these fixed dimensions as the wall could not be modified.

02
PLAN THE DISPLAY

Module Layout & Screen Design

Based on the confirmed width and height, we designed the module layout around the available space rather than changing the wall to fit a standard screen size.

03
CONTROL THE DEPTH

Structure + Electronics + Modules

The steel structure, power supplies, receiving cards, cabling and LED modules were considered as one complete installation system. Each component had to fit within the limited available depth.

04
DESIGN FOR MAINTENANCE

Front Access

With no practical rear maintenance space, the system was designed for front access so the LED modules and internal components could be installed and serviced directly from the front.

FINAL DESIGN PRINCIPLE
The wall did not adapt to the LED display.
The LED display was engineered to adapt to the wall.

By working within the existing space and carefully integrating every component, the system could achieve a clean installation with front maintenance without modifying the existing wall.

SOLUTION 06

Two Screens, Two Different Installation Conditions

The project included two LED screens in the same space, but with completely different installation conditions. Each screen required a solution based on the actual site environment.

01
RECESSED SCREEN

3250 × 500 mm

Existing recessed LED screen opening for a 3250 × 500 mm installation in Turkey
Existing condition
Wall recess
Screen size (W × H)
3250 × 500 mm
Main challenge
Limited depth

This screen had to fit an existing wall recess with fixed dimensions. The main challenge was the limited installation depth, so the structure, electronics and LED modules had to be planned around the available space.

02
ENTRANCE SCREEN

4750 × 750 mm

Steel structure installation for a 4750 × 750 mm entrance LED screen in Turkey
Existing condition
Standard wall surface
Screen size (W × H)
4750 × 750 mm
Main challenge
Custom steel structure

Unlike the recessed screen, this display had no strict depth limitation. A custom steel structure was installed directly on the wall to support the LED modules and integrate the power supplies, receiving cards and cabling.

KEY TAKEAWAY

Same project. Two screens. Two different installation solutions.

Different site conditions require different installation approaches. The solution should follow the actual space — not a fixed template.

SOLUTION 07

From Design to Installation

The final system was installed according to the actual site conditions defined during the planning stage.

Custom Structure

A custom steel structure was built according to the actual wall conditions.

Front Installation

LED modules and internal components were installed with front access for future maintenance.

Site Installation

The two LED displays were installed according to their respective site conditions.

PROJECT OUTCOME

Two screens. Two installation conditions.
One solution planned around the actual site.

By working with the existing space and using different installation methods, both displays were installed according to the actual conditions of the same venue.

SOLUTION 08

Project Summary

A quick overview of the key project conditions and the solutions applied on site.

SCREEN 01

3250 × 500 mm

Recessed LED Display

Existing wall recess

The display was installed in the existing recessed wall structure.

Limited installation depth

The available depth was limited and required a customized solution.

Front maintenance

Front access was used for future maintenance.

SCREEN 02

4750 × 750 mm

Entrance LED Display

Standard wall surface

The display was installed on a standard wall surface.

Custom steel structure

A custom steel structure was built for stable installation.

Direct wall installation

The display was directly installed on the steel structure.

INSTALLATION APPROACH

Designed around the actual site conditions —
not around a fixed installation template.

By working with the existing space and using different installation methods, both displays were installed according to the actual conditions of the same venue in Turkey.

ENGINEERING & SOLUTION SUPPORT

Let's Discuss Your LED Display Project

Tell us about your project requirements. Our team will help evaluate the right LED solution based on your application, environment, and technical needs.

CERTIFIED FOR GLOBAL ENGINEERING STANDARDS

LeYe Micro COB LED screen CCC certification standard
LeYe premium LED video wall KC certified for South Korea projects
leye led wall rohs compliant
leye led screen fcc certified
LED Video Wall Solutions

Get Your LED Solution Proposal

Share your project details and our engineers will get back to you with a suitable solution.

Please enable JavaScript in your browser to complete this form.

🔒 Your information is kept confidential and will only be used to respond to your project inquiry.

滚动至顶部